A/D converter setting


Pin Port ADC Special Use Setting ADC

Function

25 B00 AN00 AD ON ADC #07 (signal level changeable by VR50k)
24 B01 AN01 PGED3 AD ON ADC #06
23 B02 AN02 PGEC3 AD ON ADC #05
22 B03 AN03 C2IN2-/VMIO AD ON ADC #04
21 B04 AN04 C2IN1+/VPIO AD ON ADC #03
20 B05 AN05 C1IN2-/USBOEN AD ON ADC #02
26 B06 AN06 PGC1 AD ON ADC #08 (1/2 att for CO2 sensor)
27 B07 AN07 PGD1 O OFF PowerSW_Rfmodule
32 B08 AN08 PMA6 × AD ON (only rand)
33 B09 AN09 PMA7 × AD ON
34 B10 AN10 PMA13 × AD ON
35 B11 AN11 PMA12 I OFF Path of Vdd (Only input B11)
41 B12 AN12 PMA11 O OFF PowerSW_AD#07power
42 B13 AN13 PMA10 O OFF PowerSW_CameroPower
43 B14 AN14 PMA1 O OFF PowerSW_AD#08power (CO2sensor)
44 B15 AN15 PMA0 I OFF Vdd pass
6 C01 AN16 AD ON ADC for Battery voltage RF (1/4 att)
7 C02 AN17 AD ON ADC for Battery voltage RR (1/4 att)
8 C03 AN18 AD ON ADC for Battery voltage RC (1/4 att)
9 C04 AN19 O OFF nSS-SPI_MotorPIC
18 E08 AN20 AD ON ADC #00
19 E09 AN21 AD ON ADC #01 
91 A06 AN22 AD ON ADC of Main battery voltage (1/4 att)
92 A07 AN23 × AD ON (only rand)
93 E00 AN24 PMD0 AD ON ADC for Battery voltage LR (1/4 att)
94 E01 AN25 PMD1 AD ON ADC for Battery voltage LF (1/4 att)
98 E02 AN26 PMD2 AD ON ADC for Battery voltage LC (1/4 att)
99 E03 AN27 PMD3 AD ON  
100 E04 AN28 PMD4 AD ON  
3 E05 AN29 PMD5 × AD ON
4 E06 AN30 PMD6 × AD ON
5 E07 AN31 PMD7 × AD ON

 